TIRA 가진기 시스템
3. 관성가진기 (Inertia Shakers)상위메뉴 > |
|
|
TIRA has developed a product range of inertial shakers to simulate vibrations on large structures such as in aviation industry or big buildings. |
| System | TV 51112-IN | TV 51125-IN | |
| Shaker | S 51112-IN | S 51125-IN | |
| Amplifier | BAA 120 | BAA 500 | |
| Blower | - | TB 0080 | |
| Rated peak force (N) | Sine/Random | 125/70 | 250/150 |
| Frequency range (Hz) | DC - 2000 | DC - 20000 | |
| Max. travel (mm) | 9 | 9 | |
| Max. velocith (m/s) | 1.5/1.5 | 1.5/1.5 | |
| Max. acceleration rage (g) | Sine/Random | 0.98/0.54 | 2/1.2 |
| Axial suspension stiffness (N/mm) | 20 | 20 | |
| Effective moving mass (kg) | 0.35 | 0.53 | |
| Weight | 13 | 13 | |
| Coupling | M12 | M12 | |
| Max. power consumption at 230V (kVA) | Amp./Blower | 0.1/- | 0.4/0.46 |
| 다운로드 Data Sheet (PDF) | 다운로드PDF | 다운로드PDF | |
| System | TV 51140-IN | TV 51165-IN | |
| Shaker | S 51140-IN | S 51165-IN | |
| Amplifier | BAA 1000 | BAA 1000 | |
| Blower | TB 0140 | TB 0140 | |
| Rated peak force (N) | Sine/Random | 400/311 | 650/420 |
| Frequency range (Hz) | DC - 2000 | DC - 2000 | |
| Max. travel (mm) | 9 | 9 | |
| Max. velocith (m/s) | 1.5/1.5 | 1.5/1.5 | |
| Max. acceleration rage (g) | Sine/Random | 2.8/2 | 2.8/1.8 |
| Axial suspension stiffness (N/mm) | 56 | 98 | |
| Effective moving mass (kg) | 0.63 | 0.97 | |
| Weight | 16 | 26 | |
| Coupling | M12 | M12 | |
| Max. power consumption at 230V (kVA) | Amp./Blower | 1.22/1.4 | 1.27/1.4 |
| 다운로드 Data Sheet (PDF) | 다운로드PDF | 다운로드PDF | |